This split-coupled end-suction pump with NEMA MLE motors and ANSI flange fittings is a non-self-priming, single-stage centrifugal volute pump. It has an axial inlet port, radial outlet port, and horizontal shaft. The back pull-out design allows for motor, motor stool, cover, and impeller removal without disturbing the housing or pipework. It adheres to ISO 5199 standards with American dimensions on the pump and flanges. Inlet and outlet flanges comply with ASME 16.1/16.42 standards, supporting performance up to 175/363 PSI (12/25 bar). The mechanical shaft seal follows EN 12756 dimensions, while motors align with NEMA standards. This pump can use an MLE motor with an integrated frequency converter or connect to a CUE external frequency converter for applications in water treatment fertigation, chemigation & dosing; controls & digital groundwater management; and drip irrigation systems.